A circuit breaker in your DB, the MCB or mini circuit breaker, switches a circuit off when too much current flows, before the cable inside the wall gets hot enough to melt its insulation. That is the point people miss: the breaker protects the cable, not the kettle or the geyser. So you choose a breaker by the cable it feeds, then check the curve, the breaking capacity and that it clips into your board.
Price guideAbout R48 to R65 for a 10 to 40 A DIN rail breaker and R120 to R135 for 63 A, VAT included. Plug in breakers for older boards cost about R265 to R340A rough guide from published South African prices. The area, the term, the grade, what is included and VAT all move it.
Common house circuits and their breakers
These are common practice, not a design. The electrician sizes each circuit to the load and the cable run.
| Circuit | Usual cable | Usual breaker |
|---|---|---|
| Lights | 1.5 mm² | 10 A |
| Plugs | 2.5 mm² | 16 or 20 A |
| Geyser | 2.5 or 4 mm² | 20 or 25 A |
| Stove | 4 or 6 mm² | 32 A |
| Main switch | The supply cable | Set by the supply, often 60 or 63 A |
A 3 kW geyser draws about 13 A, which is why a 20 A breaker is common there. Try the breaker size calculator for your own load.
Curve, kA and poles in plain words
- C curve is the household norm: it rides through the short starting surge of a fridge or pump motor without tripping.
- Breaking capacity (3 kA, 4.5 kA or 6 kA on house breakers) is the fault current it can interrupt safely. Match what the electrician specifies.
- Single pole breakers switch the live; double pole switch live and neutral and take two ways in the DB board.
- DC breakers are a different product for solar panels and batteries. An AC breaker on a DC string may not break the arc.
Tripping is the breaker doing its job
If the plug circuit trips every time the heater and kettle run together, the circuit is overloaded. Swapping the 20 A for a 32 A means the 2.5 mm² cable can now carry more than it is made for, and the first sign may be a burnt wall box. The fix is moving a load to another circuit or adding one. A breaker that trips with nothing on points to a fault; call an electrician.
Fakes and the wrong fit
Unapproved breakers sold online at half the price have been opened to find a spring and no working trip mechanism. Buy with NRCS approval from a known supplier. Breakers also need to match the DB make: a loose clip or a busbar that does not seat properly can arc. Fitting one is a job for a registered electrician.
Who asks for this
- Homeowners and tenants
- A new breaker for an added plug circuit or a replacement after a burnt one.
- Landlords and body corporates
- Spare breakers in matching makes for every flat board in the building.
- Builders and renovators
- The full breaker schedule for a new house, ordered with the DB boards.
- Electricians and installers
- Boxes of 10 A and 20 A MCBs on account, plus double poles for stoves.
- Shops, offices and restaurants
- Dedicated breakers for a coffee machine, a server rack or a walk in fridge.
- Factories, mines and plants
- MCBs for control circuits beside the bigger moulded case breakers.
- Farms and lodges
- Breakers for borehole pumps and cold rooms, sized with motor starts in mind.
- Schools, clinics and municipalities
- Matched replacements for school and clinic boards during maintenance.
Frequently asked questions
What size circuit breaker for a geyser?
Commonly 20 A for a 3 kW element on 2.5 mm² cable, sometimes 25 A on 4 mm². The electrician confirms it against the cable that is actually in the wall.
Is the main switch also a circuit breaker?
Usually yes: a main switch circuit breaker, often double pole and 60 or 63 A, sits at the head of the board. Its rating follows the supply and the incoming cable, not what you would like to run.
Why do 20 amp circuit breaker prices vary so much?
Brand class, the kA rating, single or double pole, NRCS approval and whether it fits your board. A quote for a breaker that does not clip into your DB is no bargain.
Do you sell breakers?
No. We stock nothing ourselves; wholesalers and electricians near you quote on your request, with or without fitting.
Related topics
Work it out first
- Cable size calculatorLoad, length, phase and how the cable is run in: the cable size in mm² and the voltage drop out
- Breaker size calculatorAppliance watts or amps and the supply in: the current, the breaker rating and the cable usually used out
- Ohm's law calculatorAny two of volts, amps, ohms and watts in: the other two and the formulas used out